BoxSAFE CX
- Non Fire-Rated
- 8 ft x 40 ft x 8' 5"
- 50 Qty 55 Gallon Drums
- 9 Pallets or Totes
- 302 Square Feet storage
Compliant storage and rental solutions for Toluene, 2, 4-Diisocyanate (C9H6N2O2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Toluene diisocyanate is an organic compound with the formula CH₃C₆H₃(NCO)₂. Two of the six possible isomers are commercially important: 2,4-TDI and 2,6-TDI. 2,4-TDI is produced in the pure state, but TDI is often marketed as 80/20 and 65/35 mixtures of the 2,4 and 2,6 isomers respectively.
Acute Inhalation Toxicity - Vapors Category 1 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Respiratory Sensitization Category 1 Skin Sensitization Category 1 Carcinogenicity Category 2 Specific target organ toxicity (single exposure) Category 3
Dry Chemical fire suppression is recommended for Toluene, 2, 4-Diisocyanate
Guidance: Dry Chemical fire suppression is generally recommended for Toluene, 2, 4-Diisocyanate (C9H6N2O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Suitable Extinguishing Media Carbon dioxide (CO 2). Powder.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Toluene, 2, 4-Diisocyanate should account for its listed hazards, climate control needs (Store only where temperature will not exceed 125°F (52°C).), and segregation requirements. Incompatible Materials Acids, Water, Oxidizing agent
Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.
Properties: Melting Point/Range 19.5 - 21.5 °C / 67.1 - 70.7 °F Boiling Point/Range 251 °C / 483.8 °F
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Toluene, 2, 4-Diisocyanate in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Store only where temperature will not exceed 125°F (52°C).. Compatibility notes: Incompatible Materials Acids, Water, Oxidizing agent US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Toluene, 2, 4-Diisocyanate is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.
Toluene, 2, 4-Diisocyanate is listed as: Consult the SDS and applicable hazard classification. Acute Inhalation Toxicity - Vapors Category 1 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Respiratory Sensitization Category 1 Skin Sensitization Category 1 Carcinogenicity Category 2 Specific target organ toxicity (single exposure) Category 3
Dry Chemical fire suppression is generally recommended for Toluene, 2, 4-Diisocyanate (C9H6N2O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Toluene, 2, 4-Diisocyanate. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.